skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Search for: All records

Creators/Authors contains: "Saha, Renata"

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. Understanding the mechanisms of unidirectional magnetoresistance (UMR) has become an important topic for its potential application of a two-terminal spin–orbit torque device. Field sweep DC measurements have been proposed and adopted to measure the value of UMR instead of second harmonic measurements. In this paper, potential measurement errors in conventional DC measurements are investigated. Oersted field and field-like torque usually do not influence the measurement, but a large field-like torque was found to lead to an anisotropic magnetoresistance difference when the sample is not perfectly aligned with the external field. The existence of ordinary magnetoresistance was also found to contribute to a large background. In this paper, an alternative measurement method for UMR was proposed and demonstrated to address those issues related to previous DC measurements. Our work may broaden the understanding of the error sources of UMR measurements and provide a reliable DC measurement method for the characterization of UMR. 
    more » « less
  2. Abstract Flexible biosensors exhibit great potential for the detection of various biomarkers with the ability to adapt to different surface textures. Here, a lab‐on‐a‐needle biosensing platform based on ultra‐flexible giant magnetoresistance (GMR) biosensors is developed. The fabricated flexible GMR sensors exhibit a MR ratio of 5.2% and a sensitivity of 0.13%/Oe in the linear region, which are comparable to their rigid counterparts. It is found that the magnetic properties of the flexible GMR sensors remain unchanged after 500 cycles of compressive and tensile stress, indicating strong robustness even when applied to a surface that is constantly in motion. The developed platform is then employed for the detection of different concentrations of canine osteosarcoma (OSCA‐8) cells with a limit of detection (LOD) of 200 cells in 20 µL sample (104cells per mL), which demonstrate the ability to perform real‐time, sensitive, and quantitative cell detection. 
    more » « less